本文是硬盘维修,非数据恢复,在数据恢复场合切记使用!!!以下正文
硬盘通电寻道声音正常,终端提示以下错误
RW subfile error 2044 SIM Error 2044
尝试重建编译器,提示DiagError 0000500D 错误
F3 T>m0,6,2,,,,,22 Max Wr Retries = 00, Max Rd Retries = 00, Max ECC T-Level = 16, Max Certify Rewrite Retries = 0A74 DiagError 0000500D User Partition Format Failed - Elapsed Time 0 mins 00 secs R/W Sense 00000002, R/W Error 843200A6, File Error 00000000 Blk Addr 71030001, Blk Addr Type D0, Cyl 00000000, Hd 9A
尝试清SMART表,提示以下错误
F3 1>N1,,22 Init SMART Fail
以下为修复过程
F3 T>m0,2,1,,,,,22 Max Wr Retries = 00, Max Rd Retries = 00, Max ECC T-Level = 16, Max Certify Rewrite Retries = 0A74 User Partition Format 3% complete, Zone 00, Pass 00, LBA 00009A64, ErrCode 00000080, Elapsed Time 0 mins 30 secs User Partition Format Successful - Elapsed Time 0 mins 30 secs Zone re-format was skipped. F3 1>N1 Clear SMART is completed.
断电上电,应该小终端不报错了
F3 T>m0,2,1,,,,,22 Max Wr Retries = 00, Max Rd Retries = 00, Max ECC T-Level = 16, Max Certify Rewrite Retries = 0A74 User Partition Format 3% complete, Zone 00, Pass 00, LBA 00009A64, ErrCode 00000080, Elapsed Time 0 mins 30 secs User Partition Format Successful - Elapsed Time 0 mins 30 secs Zone re-format was skipped.
转载请注明:成都千喜数据恢复中心 » 希捷硬盘SIM Error 2044错误维修